This article introduces the setting method of "Light LED", which is suitable for finding the corresponding configuration barcode and completing parameter adjustment.
Applicable to:
E900
Questions
- How to set up the LED to light up?
- Where is the configuration barcode to light up the LED?
- How to adjust the parameters of lighting LED?
Resolution / Answer
This article introduces the use and configuration method of "Light LED". Usually refer to this article when you need to change the default behavior of the device, adapt to the business system, or find the corresponding configuration barcode.
Let the scanner illuminate the designated LED indicator for a period of time. When executing this command, the scanner will not scan and read codes. Before using this function, you need to check which colors of LED indicators on the scanner support this function.
Command parameters:
C represents LED color: 0C - red, 1C - white, 2C - green, 3C - blue
D represents the duration of LED lighting, in milliseconds, and the value range is 10 - 3600000.
Send: LEDONS$, $ represents Data. When Data is '*' or '&', the response is: LEDONS<ACK>; when Data is '^', the response is: LEDONS0C10-3600000D<ACK>;
The red LED lights up for 1 minute:
Send ~<SOH>0000#LEDONS0C60000D;<ETX>
Response <STX><SOH>0000#LEDONS0C60000D<ACK>;<ETX>
If this does not resolve the issue, please reset the barcode scanner or contact us. Click here to find your barcode scanner model and perform the reset.