M8BT Barcode Scanner Support Guide
This page primarily collects and categorizes configuration methods for barcode scanners. You can click to jump to the specific operation page based on your required issue.
System Information and Settings
Information about firmware, system, module identity.
Scanning / Triggering Behavior
How the engine reads, detects, or stays idle.
Data Formatting & Output Rules
All data manipulation after decoding.
Communication Settings
Physical and wireless communication settings.
Wired
Wireless
Others
Model-Specific Configuration Articles
Additional settings that apply to this scanner model.
Scanning / Triggering Behavior
How the scanner reads, detects, triggers, repeats, or times out.
- Continued scanning
- Custom sensitivity
- How to enable or disable passive trigger scanning
- How to quickly set a single scan time (scan duration)
- How to quickly set the same code delay
- The continuous reading interval
- The same code delay
- The same code in a single round of decoding not to be output
- The sensitivity level
- The single scan time (scan duration)
- The stable sensing time
- Trigger mode
Communication Settings
USB, RS-232, serial, keyboard, and host communication settings.
- Data bits
- How to enable or disable barcode caching
- How to enable or disable Modbus Rtu function
- How to enable or disable RS485 network heartbeat
- How to enable or disable RS485 networking function
- How to modify the slave address of 485 device
- How to quickly set the keyboard output time interval
- How to quickly set the slave address
- How to select country/language keyboard layout
- How to select stop bit
- How to select the ASCII control character output method
- Keyboard output to force letter case conversion
- RS485 networking decoding data to be saved in cache
- Software handshake
- The baud rate
- The communication method
- The host serial response timeout
- The keyboard output character time interval
- The keyboard type
- The parity bit
- The RS485 network decoding data format
- The slave address
- The Wiegand 26 protocol output mode
- The Wiegand output time interval
- The Wiegand protocol type
- USB type
Beeper / Indicator Settings
Beeper, LED, vibration, and other output feedback settings.
Other Configuration Settings
Additional configuration articles for this model.
- 1D inverted barcode reading
- Check code verification
- Codabar length
- Codabar to send check characters
- Codabar verification
- Code 11 length
- Code 128
- Code 128 to send check characters
- Code 32 check code verification
- Code 39 check digit verification
- Code 93 length
- Data Matrix forward/reverse phase reading
- Discrete 2 of 5 calibration
- Discrete 2 of 5 length
- Discrete 2 of 5 to send check characters
- EAN-13 2-digit additional code
- EAN-13 Additional code must be read
- EAN-13 to send check characters
- EAN-8 2-digit additional code
- EAN-8 Additional code must be read
- EAN-8 to send check digit
- EAN-8 zero extension
- Factory default configuration
- Hansein code positive/reverse phase reading
- Hexadecimal output
- How to change the setup code password
- How to configuration barcode parameter prompt tone
- How to control Data Matrix ECI
- How to control heartbeat
- How to control positioning light
- How to control QR ECI
- How to control the decoding indicator
- How to control the light
- How to enable or disable Code 11
- How to enable or disable Code 128
- How to enable or disable Code 39
- How to enable or disable Code 39 Full ASCII
- How to enable or disable Code 93
- How to enable or disable MSI
- How to enable setup code password mode
- How to enter the setup code password
- How to log out password
- How to quickly set the length of retained header data
- How to quickly set the length of retained intermediate data
- How to quickly set the length of retained tail data
- How to quickly set the starting position of retaining intermediate data
- How to send setup code
- I 2 of 5 check code verification
- ISBT 128
- ISSN
- Linear code type safety level
- Linear security level 1
- Linear security level 2
- Linear security level 3
- Linear security level 4
- Matrix 25 check digit verification
- MSI check code algorithm
- MSI check digit
- MSI length
- Mute
- NEC-25(COOP25) to send check characters
- NEC-25(COOP25) verification
- NOTIS Edit
- Output product information
- PDF417 forward/reverse phase reading
- Positioning light
- QR forward/reverse phase reading
- Retain header data
- Retaining tail data
- Retention of intermediate data
- RSS AI characters
- Scanning configuration barcode
- Sending "Not Read
- Standard 25 check digit verification
- Support for GS1 rules and use brackets to include AI fields
- The boot tone
- The buzzer type
- The buzzer volume
- The Code 39 length
- The Code 39 transmission start character and suffix terminator
- The conversion from Code 39 to Code 32 (Italian Medical Code)
- The conversion UPC-E to UPC-A
- The decoded packet format
- The decoding success indicator light
- The decoding success sound
- The EAN-13 5-digit additional code
- The EAN-8 5-digit additional code
- The indicator function
- The Interleaved 2 of 5 length
- The invoice function
- The invoice type
- The length of Code 128
- The length of Matrix 25
- The length of retained header data
- The length of retained intermediate data
- The length of retained tail data
- The letter case of the start character and suffix terminator
- The NEC-25 (COOP 25) length
- The power mode
- The power-on event
- The Standard 25 length
- The start character and suffix terminator format
- The starting position of retaining intermediate data
- The suffix terminator
- The transmission check character
- The transmission Code 11 check digit
- The transmission Code 32 check digit
- The transmission Code 39 check digit
- The transmission code ID character
- The transmission Matrix 25 check character
- The transmission MSI check code
- The transmission UPC-A check digit
- The transmission UPC-E check digit
- The UTF-8 BOM encoding format to remove QR code
- To hexadecimal interval output
- Transmission I 2 of 5 check digit
- Trigger reading event
- Turn Codabar on or off
- Turn on or off 1D code
- Turn on or off all barcodes
- Turn on or off Aztec Code
- Turn on or off Bookland EAN(ISBN)
- Turn on or off COMPOSITE
- Turn on or off Data Matrix(DM)
- Turn on or off Discrete 2 of 5
- Turn on or off EAN-13
- Turn on or off EAN-8
- Turn on or off GS1 DataBar/RSS
- Turn on or off GS1-128 (formerly UCC/EAN-128)
- Turn on or off Han Xin Code
- Turn on or off Interleaved 2 of 5
- Turn on or off Matrix 25
- Turn on or off Maxi Code
- Turn on or off NEC-25(COOP25)
- Turn on or off PDF417
- Turn on or off QR
- Turn on or off QR code
- Turn on or off Standard 25
- Turn on or off the configuration barcode password mode
- Turn on or off UPC-A
- Turn on or off UPC-E
- Turn on or off UPC-E1
- UCC/EAN-128 length
- UCC/EAN-128 to send check characters
- UPC-A 2-digit additional code
- UPC-A 5-digit additional code
- UPC-A preamble
- UPC-A. Additional code must be read
- UPC-E 2-digit additional code
- UPC-E 5-digit additional code
- UPC-E preamble
- UPC-E. Additional code must be read
- URL blocking
- VAT invoice automatic recognition output
- Whether the positioning light flashes